ORIGINAL ARTICLE
Year : 2015  |  Volume : 2  |  Issue : 1  |  Page : 23-28

Effects of mobile phone radiation on heart rate variability of healthy young subjects


1 Department of Physiology, Government Medical College, Bhavnagar, Gujarat, India
2 Department of Physiology, Pecific Medical College, Udaipur, Rajasthan, India

Date of Submission04-Feb-2015
Date of Decision12-Mar-2015
Date of Acceptance24-Mar-2015
Date of Web Publication21-Apr-2015

Correspondence Address:
Anup M Vegad
Department of Physiology, Government Medical College, Bhavnagar, Gujarat
India
Login to access the Email id

Source of Support: Directorate of Medical Education and Research, Gandhinagar, Gujarat, India., Conflict of Interest: None


DOI: 10.4103/2348-8093.155508

Rights and Permissions
  Abstract 

Background and Aim: The potential health risk of the radiofrequency electromagnetic fields which are emitted by mobile phones (MPs) is of considerable public interest. The aim of the present study was to determine the influence of the call with a MP on heart rate variability (HRV) in healthy young male and female subjects.
Methods: Heart rate variability was measured in 100 young healthy subjects of either sex from 5 min continuous recording of heart rate using windows-based HRV analysis system during three conditions: (1) When MP is switched off (Period I) (2) when MP is switched on (Period II) (3) during call on MP for 5 min (Period III).
Results: In female subjects, we found that the time domain parameters like root of the mean of the sum of the squares of differences between adjacent NN intervals, standard deviation of differences between adjacent NN intervals, NN50, pNN50 were significantly reduced during Period II and Period III as compared to Period I. Furthermore, the frequency domain parameters such as low frequency (LF) and LF/high frequency (HF) were significantly increased during Period II and Period III as compared to Period I. Whereas HF was significantly reduced during Period II and Period III as compared to Period I in female subjects. In the male, only NN50 count was significantly reduced during Period II and Period III as compared to Period I.
Conclusion: Increase in the sympathetic tone concomitant with the decrease in the parasympathetic tone was observed during the MP usage in female subjects. However, only the parasympathetic tone may be reduced in male subjects while using MPs.

Keywords: Autonomic balance, electromagnetic fields, heart rate variability, mobile phone


How to cite this article:
Vegad AM, Kacha YK, Varu MS, Mehta HB, Shah CJ. Effects of mobile phone radiation on heart rate variability of healthy young subjects. Int J Clin Exp Physiol 2015;2:23-8

How to cite this URL:
Vegad AM, Kacha YK, Varu MS, Mehta HB, Shah CJ. Effects of mobile phone radiation on heart rate variability of healthy young subjects. Int J Clin Exp Physiol [serial online] 2015 [cited 2019 Jan 18];2:23-8. Available from: http://www.ijcep.org/text.asp?2015/2/1/23/155508


  Introduction Top


Recent years have witnessed rapid worldwide growth in the use of cell phone and enormous attention about its effect on human health. Mobile phones (MPs) radiation might induce or promote cancer, and the symptoms which are associated with their use include sleep disturbances, memory problems, headaches, nausea, dizziness and changes in the electroencephalographic activity. [1] The Global System for Mobile Communication MPs are low power radio devices that receive and transmit electromagnetic fields (EMFs). According to the present standards, the maximum powers that MP is permitted to transmit are 2 and 1 W for 900 and 1800 MHz, respectively. [2],[3] According to European Guidelines, the specific absorption rate (SAR) limit for hand-held devices is 2.0 W/kg averaged over 10 g of tissue. SAR levels according to American guidelines requires hand-held devices to be at or below 1.6 W/kg measured over 1.0 g of tissue. For whole body exposures, the limit is 0.08 W/kg. India switched from the European limits to the American limits for mobile handsets in 2012. [4] Malaric et al. measured the EMF emitted by MP in various conditions and noticed that these measures are much higher particularly during preparing handshaking, ringing and sending short message service message than while speaking. [5] The analysis of heart rate variability (HRV) is a noninvasive clinical technique for indirectly investigating the cardiac and autonomic nervous system in both healthy and diseased subjects. HRV signals are analyzed using linear and nonlinear techniques. [6] Frequency domain and time domain parameters have been recommended for HRV analysis with 5 min recordings. [7] Reduced HRV predicts ominous clinical output in various conditions and it is associated with increased risk of mortality and susceptibility to life-threatening arrhythmias. [8],[9] EMFs emitted by MPs may alter cardiac autonomic regulation. Studies conducted by Barutcu et al. [10] and Tamer et al. [11] shows that short-term exposure to EMFs emitted by a MPs has no effect on short-term HRV parameters in healthy subjects. Studies conducted by Andrzejak et al. [12] and Al-Hazimi. [13] shows that the increase in the parasympathetic tone concomitant with the decrease in the sympathetic tone measured indirectly by analysis of HRV were observed during the mobile call. A study conducted by Stars et al. [14] shows that maximum strong radiation emitted from cellular phones can lead to increase in parasympathetic autonomic activity of young and healthy individuals. A study conducted by Kodavanji et al. [15] shows that the mobile users had a higher sympathetic tone and a lower parasympathetic tone as compared with the mobile nonusers. Thus, effects of MP radiation on HRV still remains inconclusive, and all the previous studies does not exclude the effects of speaking and emotions related to talking during mobile call on HRV. Therefore, the present study was designed to test the possible effects of radiofrequency waves emitted by MPs on cardiac autonomic modulation by short-term HRV analysis. We used Nokia X2 MP (highest SAR value for use of this device at the ear is 0.82 W/kg) for our research project. We avoided actual speaking during the call to avoid effects of speaking and emotions related to talk on autonomic nervous system, but mobile call was going on during recording of HRV so we can get conclusive results.


  Materials and methods Top


After obtaining the permission of Institutional Review Board and Ethical Committee, the study was carried out at autonomic function laboratory, Physiology department, Government Medical College and Sir T Hospital, Bhavnagar. Written informed consent was taken from all participants before allotment to study. The study group was comprised of 100 young healthy subjects of either sex (male: 60, female: 40, age group: 17-25). Subjects were enrolled from of students and staff members of Government Medical College, Bhavnagar. Subjects aged between 17 and 25 years of either sex and with the ability to give written informed consent was included in the study.

Exclusion criteria

  • Presence of any serious cardiovascular disease including arterial hypertension, ischemic or rheumatic heart diseases, serious arrhythmias, left ventricular dysfunction, diabetes mellitus, etc
  • Presence of metabolic and neurological disorders could influence the HRV
  • Subjects taking drugs affecting cardio-respiratory response (anti psychotics, antidepressants, antiarrhythmic)
  • Subjects consuming alcohol and smokers
  • Patient having implanted pacemaker
Detail history taking and clinical examination of every subject were done before the HRV measurement. Pulse and blood pressure were also recorded. We follow the standard procedure of measurement of short-term HRV. The changes in the HR were measured with an instantaneous HRV software (Variowin-HR) interfaced with a microcomputer.

Pretest preparations

Subjects should not to eat, drink, etc., at least half an hour prior to test as this result in a shift of results. Subjects will be advised to abstain from consuming caffeinated beverages and excessive physical activity including gymnastics within 12 h preceding data collection. Subjects should abstain from the drugs which are known to affect the HR for at least 24 h before the test. Subjects must be allowed to relax for 10-20 min before starting the test. Test should be done in relaxed supine position. Allow the normal pattern of breathing. HRV recording was done in the morning time between 9:00 and 11:00 am in a semi-darkened, temperature controlled, quiet laboratory at room temperature (21°). HRV was measured from 5 min continuous recording (short-term HRV) of HR (based on r-r interval) using windows-based HRV analysis system Variowin-HR with 100% accuracy during 3 conditions: (1) Basal condition when MP is switched off (Period I) (2) when MP is switched on (Period II) (3) during call with of MP for 5 min when MP is attached to right ear of subject with a band (Period III). We used Nokia X2 MP for our research project. The highest SAR value for use of this device at the ear is 0.82 W/kg. We avoid actual speaking during the call to avoid effects of speaking and emotions related to talk on autonomic nervous system, but the mobile call was switched on during recording of HRV. We measured the following time domain such as standard deviation of all NN intervals (SDNN), standard deviation of the averages of NN intervals in all 5 min segments of the entire recording (SDANN), The square root of the mean of the sum of the squares of differences between adjacent NN intervals (RMSSD), standard deviation of differences between adjacent NN intervals (SDSD), number of pairs of adjacent NN intervals differing by more than 50 ms in the entire recording (NN50 count), NN50 count divided by the total number of all NN intervals (pNN50), triangular HRV index and frequency domain parameters during HRV measurements such as very low frequency (VLF), LF, high frequency (HF) and LF:HF ratio.

Statistical analysis of data

All the data were expressed in the form of mean ± S.D. We used GraphPad InStat 3 (GraphPad Software

Inc., San Diego, CA, USA) demo version software for statistical analysis. Statistical analysis was done by one-way ANOVA test followed by post-hoc Tukey test among 3 phases. P <0.05 was taken as a statistically significant.


  Results Top


All study subjects had sinus rhythm. They had normal systolic and diastolic blood pressure [Table 1]. There was no any significant difference in all the time domain parameters in male subjects during recording of HRV in three different periods except NN50 count. NN50 count was significantly reduced when MP was switched on and during the call with MP as compared to theirs basal values when MP was switched off [Table 2]. There was no significant difference in all frequency domain parameters in male subjects during recording of HRV in three different periods [Table 3]. While recording HRV in female subjects, we have found that the time domain parameters such as RMSSD, SDSD, NN50, pNN50 were significantly reduced when MP was switched on and during call with MP as compared to their basal values when MP was switched off. There was no significant difference in other time domain parameters in female subjects during recording of HRV in three different periods [Table 4]. We also found that in female subjects frequency domain parameters such as LF and LF/HF were significantly increased when MP was switched on and during call with MP as compared to their basal values when MP was switched off. Whereas, HF was significantly reduced when MP was switched on and during the call, compared to their basal values when MP was switched off [Table 5].
Table 1: Anthropological and other parameters


Click here to view
Table 2: Time domain HRV parameters in male subjects


Click here to view
Table 3: Frequency domain HRV parameters in male subjects


Click here to view
Table 4: Time domain HRV parameters in female subjects


Click here to view
Table 5: Frequency domain HRV parameters in female subjects


Click here to view



  Discussion Top


The present study demonstrated that the call with the use of a MP may cause the increase in sympathetic tone and the decrease in parasympathetic tone particularly in female subjects. It is known that the efferent vagal activity is a major contributor to the HF component. [16],[17],[18] On the other hand, LF is a marker reflecting both sympathetic and vagal activity and the LF/HF ratio is considered to mirror of sympathovagal balance or reflect the sympathetic modulations. [17],[19] While recording time domain parameters HRV, SDNN reflects the total power, SDANN reflects ultralow frequency power, SDNN index reflects VLF power and LF power while SDSD, RMSSD, NN50 count and pNN50 reflects HF power. [20]

In our study mean HR did not change significantly during HRV recording of different three conditions [Table 2] and [Table 4]. These findings are similar to other studies done previously. [10],[11],[12],[13],[14] In our study while recording HRV time domain parameters in female subjects we found that RMSSD values were significantly reduced when MP was switched on (period II) and during call with MP (period III) as compared to their basal values when MP was switched off (period I) (P = 0.0148, I-III: 0.0330, II-III: 0.0495) as per [Table 4]. SDSD values were significantly reduced when MP was switched on (period II) and during call with MP (period III) as compared to their basal values when MP was switched off (P = 0.0138, I-III: 0.0315, II-III: 0.0476) as per [Table 4]. NN50 values were significantly reduced when MP was switched on (period II) and during call with MP (period III) as compared to their basal values when MP was switched off (P = 0.0017, I-III: 0.0092, II-III: 0.0151) as per [Table 4]. pNN50 values were significantly reduced when MP was switched on (period II) and during call with MP (period III) as compared to their basal values when MP was switched off (P = 0.0053, I-III: 0.0176, II-III: 0.0281) as per [Table 4]. There was no any significant difference found in other time domain parameters in female subjects during recording of HRV in three different periods.

In our study we have also found in female subjects that the frequency domain parameters like LF values were significantly increased when MP was switched on and during call with MP as compared to their basal values when MP was switched off (P < 0.0001, I-III: 0.0002, II-III: 0.0002) as per [Table 5]. Furthermore, LF/HF ratio values were significantly increased when MP was switched on and during call with MP as compared to their basal values when MP was switched off (P < 0.0001, I-III: 0.0004, II-III: 0.0003) as per [Table 5]. HF values were significantly reduced when MP was switched on and during call with MP as compared to their basal values when MP was switched off (P < 0.0003, I-III: 0.0033, II-III: 0.049) as per [Table 5].

There was no any significant difference found in all the time domain and frequency domain parameters in male subjects during recording of HRV in three different periods except NN50 count. NN50 count was significantly reduced when MP was switched on and during call with MP as compared to their basal values when MP was switched off (P = 0.0018, I-III: 0.0111, II-III: 0.0068) as per [Table 3].

Our findings are not similar with findings of other previous studies. Barutcu et al. [10] and Tamer et al. [11] found that neither frequency nor time domain HRV parameters altered significantly during turn on and calling mode compared to their baseline values. Andrzejak et al. [12] and Al-hazimi [13] have reported that during 15-20 min call with a MP, the parasympathetic tone was increased whereas the sympathetic tone was lowered during the call with use of a MP. Stars et al. [14] also found that due to the radiation emitted from the MP at maximum power, some changes may occur that are associated, with the parameters of HRV with increased parasympathetic activity.

Hence, here in our study we found reduced values of time domain parameters in female subjects such as RMSSD, SDSD, NN50, pNN50 during call with MP and when MP was switched on. Also frequency domain parameters in female subjects like LF and LF/HF were significantly increased while HF was significantly reduced when MP was switched on and during call with MP. This suggests that increase in the sympathetic tone concomitant with the decrease in parasympathetic tone measured indirectly by HRV was observed during call with MP mainly in female subjects our study. We found opposite results as compared to majority of previous studies which shows that there is increase in parasympathetic tone during call with MP. While in male subjects only NN50 count was significantly reduced when MP was switched on and during call as compared to their basal values when MP was switched off. Hence, vagal activity decreased during MP call and when MP was switched on. Results of our investigation suggest that a call with use of a MP may exert a noticeable effect on autonomic balance; the pattern it represents is typical for the deleterious effect on HRV, that is, lack of a typical decrease in parasympathetic activity with the domination of sympathetic system.

It was demonstrated that change in forearm position may have an impact on sympathetic nerves in muscles of the hand. [21] However, reports are concentrated on forearm raise together with handgrip exercises performed more or less intensively, which could cause the increase in sympathetic activity. [21],[22] Hence, to avoid these effects we measured HRV in lying down position, and MP was attached to right ear of the subject with a rubber band. Speaking can increase the speed of breathing and, therefore, changes in respiratory frequency may have an influence on HR. [23],[24] Reading aloud and free talking may increase LF component. [24] Hence, we avoided actual speaking during the call to avoid effects of speaking and emotions related to talk on autonomic nervous system. Gender difference found in our study can be explained by some previous studies. Studies carried out by Cowan et al. [25] and Stein et al. [26] shows that there is low parasympathetic and high sympathetic activity in females as compared to males. Psychogenic influences play a major role in females for this autonomic tone difference. Regarding widespread use of MPs nowadays closer attention should be paid to a problem of workers who use MPs for a long time and are occupationally exposed to EMF.

Limitations of the study

The sample size of the present study was moderate and, therefore, the results obtained could not be directly applied to the general population. Furthermore, in the present study only short-term HRV was recorded. In such studies, inclusion of 24 h HRV would be more informative and reliable to validate the results.


  Conclusion Top


Results of our study demonstrate that the call with a MP may influence HRV and change the autonomic balance. The increase in the sympathetic tone with a concomitant decrease in the parasympathetic tone measured indirectly by analysis of HRV was observed during the MP call particularly in female subjects. Parasympathetic tone may be reduced in male subjects while using MPs. Thus, MP may exert a deleterious effect on HRV.

 
  References Top

1.
Maier M, Blakemore C, Koivisto M. The health hazards of mobile phones. BMJ 2000;320:1288-9.  Back to cited text no. 1
[PUBMED]    
2.
Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz). International Commission on Non-Ionizing Radiation Protection. Health Phys 1998;74:494-522.  Back to cited text no. 2
[PUBMED]    
3.
CENELEC, (European Committee for Electrotechnical Standardization). Basic standard for the measurement of specific exposure rate related to human exposure to electromagnetic fields from mobile phones (300 MHz- 3 GHz), (EN 50361: 2001E). 2001.  Back to cited text no. 3
    
4.
Stringent Mobile Radiation Standards Come into Force from tomorrow New Mobile Handsets to comply with SAR Value of 1.6W/KG-Penalty, Random Checks Introduced for Enforcement. Press Information Bureau, Government of India; 2012.  Back to cited text no. 4
    
5.
Malaric K, Bartolic J, Malaric R, Measurement of GSM Phone Emission. Instrumentation and Mesurement Technology Conference-IMTC, Como, Italy; 2004.  Back to cited text no. 5
    
6.
Kleiger RE, Stein PK, Bigger JT Jr. Heart rate variability: Measurement and clinical utility. Ann Noninvasive Electrocardiol 2005;10:88-101.  Back to cited text no. 6
    
7.
Heart rate variability: Standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Circulation 1996;93:1043-65.  Back to cited text no. 7
[PUBMED]    
8.
Tsuji H, Venditti FJ Jr, Manders ES, Evans JC, Larson MG, Feldman CL, et al. Reduced heart rate variability and mortality risk in an elderly cohort. The Framingham Heart Study. Circulation 1994;90:878-83.  Back to cited text no. 8
    
9.
Kleiger RE, Miller JP, Bigger JT Jr, Moss AJ. Decreased heart rate variability and its association with increased mortality after acute myocardial infarction. Am J Cardiol 1987;59:256-62.  Back to cited text no. 9
[PUBMED]    
10.
Barutcu I, Esen AM, Kaya D, Turkmen M, Karakaya O, Saglam M, et al. Do mobile phones pose a potential risk to autonomic modulation of the heart? Pacing Clin Electrophysiol 2011;34:1511-4.  Back to cited text no. 10
    
11.
Tamer A, Gündüz H, Ozyildirim S. The cardiac effects of a mobile phone positioned closest to the heart. Anadolu Kardiyol Derg 2009;9:380-4.  Back to cited text no. 11
    
12.
Andrzejak R, Poreba R, Poreba M, Derkacz A, Skalik R, Gac P, et al. The influence of the call with a mobile phone on heart rate variability parameters in healthy volunteers. Ind Health 2008;46:409-17.  Back to cited text no. 12
    
13.
Al-Hazimi A. Effects of the call with the mobile phone on heart rate variability parameters of healthy young people. J Chem Pharm Res 2011;3:734-40.  Back to cited text no. 13
    
14.
Stars T, Yilmaz D, Guler B, Akgüllü C. Radiation from mobile phones on the effects of short-term heart rate variability parameters-original research. Antolian J Cardiol 2012.  Back to cited text no. 14
    
15.
Kodavanji B, Mantur VS, Kumar NA, Pai SR. A pilot study on long term effects of mobile phone usage on heart rate variability in healthy young adult males. J Clin Diagn Res 2012;6:346-9.  Back to cited text no. 15
    
16.
Malliani A, Pagani M, Lombardi F, Cerutti S. Cardiovascular neural regulation explored in the frequency domain. Circulation 1991;84:482-92.  Back to cited text no. 16
    
17.
Akselrod S, Gordon D, Ubel FA, Shannon DC, Berger AC, Cohen RJ. Power spectrum analysis of heart rate fluctuation: A quantitative probe of beat-to-beat cardiovascular control. Science 1981;213:220-2.  Back to cited text no. 17
[PUBMED]    
18.
Pomeranz B, Macaulay RJ, Caudill MA, Kutz I, Adam D, Gordon D, et al. Assessment of autonomic function in humans by heart rate spectral analysis. Am J Physiol 1985;248:H151-3.  Back to cited text no. 18
[PUBMED]    
19.
Appel ML, Berger RD, Saul JP, Smith JM, Cohen RJ. Beat to beat variability in cardiovascular variables: Noise or music? J Am Coll Cardiol 1989;14:1139-48.  Back to cited text no. 19
    
20.
Camm AJ, Malik M, Bigger JT Jr, Breithardt G, Cerutti S, Cohen RJ, et al. Heart rate variability: Standards of measurements, physiological interpretation and clinical use. Circulation 1996;93:1043-65.  Back to cited text no. 20
    
21.
Kamiya A, Michikami D, Fu Q, Niimi Y, Iwase S, Mano T, et al. Static handgrip exercise modifies arterial baroreflex control of vascular sympathetic outflow in humans. Am J Physiol Regul Integr Comp Physiol 2001;281:R1134-9.  Back to cited text no. 21
    
22.
Ichinose M, Saito M, Wada H, Kitano A, Kondo N, Nishiyasu T. Modulation of arterial baroreflex control of muscle sympathetic nerve activity by muscle metaboreflex in humans. Am J Physiol Heart Circ Physiol 2004;286:H701-7.  Back to cited text no. 22
    
23.
Novak V, Novak P, de Champlain J, Le Blanc AR, Martin R, Nadeau R. Influence of respiration on heart rate and blood pressure fluctuations. J Appl Physiol (1985) 1993;74:617-26.  Back to cited text no. 23
    
24.
Bernardi L, Wdowczyk-Szulc J, Valenti C, Castoldi S, Passino C, Spadacini G, et al. Effects of controlled breathing, mental activity and mental stress with or without verbalization on heart rate variability. J Am Coll Cardiol 2000;35:1462-9.  Back to cited text no. 24
    
25.
Cowan MJ, Pike K, Burr RL. Effects of gender and age on heart rate variability in healthy individuals and in persons after sudden cardiac arrest. J Electrocardiol 1994;27 Suppl: 1-9.  Back to cited text no. 25
    
26.
Stein PK, Kleiger RE, Rottman JN. Differing effects of age on heart rate variability in men and women. Am J Cardiol 1997;80:302-5.  Back to cited text no. 26
    



 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
   Abstract
  Introduction
   Materials and me...
  Results
  Discussion
  Conclusion
   References
   Article Tables

 Article Access Statistics
    Viewed2361    
    Printed27    
    Emailed0    
    PDF Downloaded235    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]